what size home battery

  • What size solar battery do I need for my home?
    What size solar battery do I need for my home? May 03, 2025
    The right battery size is not the biggest one you can afford, and it is not the one a neighbour bought. A battery that is too small runs out on the evening you need it most; one that is too large costs more than it will ever save. The number comes from three things: how much electricity the loads you care about actually use, how long you want them to run without the grid, and how much of that energy the battery can realistically deliver. There is a fourth factor that most sizing guides skip, and it is the one that decides whether the system works: power. A battery is measured in kilowatt-hours, but the inverter that sits between it and your house is measured in kilowatts, and the two are not interchangeable. We will come back to that after the energy side is settled. Step 1: Build your load profile Start from your electricity bill, which already states daily or monthly kilowatt-hours. It is a far better starting point than a list of appliances, because appliance lists always miss something and always overestimate how long each one runs. Start from the bill, not the appliance list Take a winter month, divide the total by the number of days, and you have your daily consumption. Do the same for a summer month. The gap between the two tells you how much of your load is seasonal, which matters later when you decide how many days of autonomy to buy. Then separate the loads you want to keep running from the ones you can live without. This is not the same as the loads you use most. An electric oven draws a lot of power for a short time and is easy to skip during an outage. A refrigerator draws little but runs around the clock and spoils food if it stops. What belongs on the critical list Refrigeration, lighting, internet and phone charging, a fan or a small heat-pump circuit, and any medical equipment usually make the list. Electric ovens, clothes dryers, water heaters and whole-house air conditioning usually do not, unless the point of the system is comfort rather than survival. To turn the list into a number, read the nameplate power of each appliance and multiply by the hours it runs. A 150 W refrigerator cycling for 8 hours a day uses about 1.2 kWh. A 10 W router running continuously uses 0.24 kWh. Add them up and you have your daily critical load. For scale: a small efficient home might land near 5 kWh, a typical family home around 10 to 15 kWh, and a large home with electric heating considerably more. If your number comes out above 20 kWh, check it. Something has been left running that does not need to be on the backup circuit. If your main goal is savings rather than backup, look at your utility's time-of-use schedule instead. Under a plan with a clear peak and off-peak gap, the battery needs to cover a meaningful share of your evening consumption. Where rates are flat all day, size mainly for backup and solar self-consumption. Treat any tariff figure you read online as illustrative, including the ones in this article. Rates differ by utility and change. Step 2: Decide your backup target Next, decide how long the essential loads must run on their own. This single decision has the largest effect on cost, because it multiplies everything above. Target What it covers Usable energy Basic backup Lights, refrigerator, communications through a short outage 3 to 5 kWh Comfort backup Adds heating or cooling, water heating and kitchen circuits 8 to 15 kWh Whole house or off-grid The full home for a day or more, often with a generator for long stretches 20 kWh and up One night is the normal target Most grid-connected homes aim to cover one evening and night until solar returns. That is effectively a one-day target, and it is the sweet spot for cost. You are not buying independence from the grid. You are buying the ability to get through the hours when the panels produce nothing and the grid is down. Two days is a different project Off-grid homes and sites with unreliable supply often want two days or more to ride through cloudy weather. Be clear about what that doubles: not just the battery, but the cost, the wall space and the weight. A 15 kWh system becomes a 30 kWh system, and the second 15 kWh rarely earns anything back on a grid-connected site. Where outages lasting several days are rare, a smaller battery plus a generator is usually cheaper than a battery sized for the worst case. The battery handles the first night silently and automatically, which is what most people actually want, and the generator covers the exceptional event. Step 3: Apply depth of discharge and efficiency You cannot use 100 percent of a battery's nameplate capacity repeatedly without shortening its life. The usable share is set by the recommended depth of discharge, and some energy is lost in the inverter, the cabling and the cells themselves. Battery capacity (kWh) = daily critical load × backup days ÷ (DoD × system efficiency) What depth of discharge costs you Lithium iron phosphate systems commonly allow about 90 percent depth of discharge, which means a 10 kWh battery gives you roughly 9 kWh before the BMS steps in. Running at the limit every day is possible but not kind. Most manufacturers rate cycle life at 80 percent depth of discharge for a reason, and a system that cycles at 90 percent day after day will reach its end-of-life figure sooner than the datasheet suggests. This is why sizing at 90 percent and running at 80 percent is a sensible habit. The extra capacity you buy as margin is not wasted. It is the difference between a battery that still holds its rated energy in year eight and one that does not. Efficiency is a round trip Round-trip efficiency for a residential LFP system usually lands between 85 and 92 percent at the system level. The cells themselves return 92 to 96 percent; the gap is the power electronics and the standby draw. In the formula above, 0.9 is a reasonable planning figure, slightly optimistic for a low-voltage system and about right for a high-voltage one. Note that this loss applies only to energy that passes through the battery. Solar used directly in the house never touches it, so a system with high self-consumption during the day pays less of this penalty than one that stores everything. Worked example Suppose the essential loads total 12 kWh per day. For one night of backup with a depth of discharge of 0.9 and system efficiency of 0.9: 12 × 1 ÷ (0.9 × 0.9) = 12 ÷ 0.81 = 14.8 kWh Rounding up gives headroom, so a system around 15 to 20 kWh fits a one-night target. Note the distinction between nominal and usable capacity: a battery sold as 15 kWh delivers less than that to the wall, so always size from usable energy rather than the figure on the box. The same house at two days Double the target and the requirement becomes 29.6 kWh, which in practice means 30 kWh or more. That is two stacked modules beyond the one-night case, twice the weight on the wall, and roughly double the cost. Before committing, compare it against the price of a small generator and ask how often your grid actually fails for more than 24 hours. Adding an EV or a heat pump An electric vehicle driven 40 km a day adds roughly 6 to 8 kWh of overnight demand. A heat pump in a cold climate can add far more, sometimes 20 kWh a day in January. Neither is a reason to double the battery on day one, because both are easy to schedule outside the backup window. What they change is the value of expansion later, which is worth planning for even if you do not buy the capacity now. Power rating matters as much as capacity This is where sizing goes wrong most often. Kilowatt-hours describe how long the battery can run a load. Kilowatts describe how much load it can run at once. A 20 kWh battery paired with a 3 kW inverter will not run a 6 kW shower, no matter how full it is. Measure Answers Set by Limits kWh (energy) How long can I run this? Battery capacity Overnight duration kW (power) What can I run at the same time? Inverter rating Simultaneous load and surge Capacity sets the hours; power sets the appliances. Both have to fit the same house. kW starts the load, kWh runs it Add up the appliances that will be on at the same time, not the total connected load. A house with 15 kW of connected appliances might peak at 4 kW in practice, because the oven, the dryer and the shower rarely run together. That peak figure, plus 20 to 30 percent headroom, is the inverter rating you need. The surge most systems miss Motors draw three to five times their running current for the first 200 to 500 milliseconds. An air conditioner compressor is the classic case. An inverter rated at 150 percent for 20 milliseconds supplies that surge for less time than the compressor takes to come up to speed, so the backup output trips even though the numbers looked fine on paper. The practical answers are a larger inverter, a soft starter on the compressor, or a decision that the air conditioner stays off the backup circuit. Choosing which loads sit behind the backup output is part of sizing, not an afterthought. What changes the number in practice Cold weather Lithium iron phosphate loses usable capacity as it cools. Expect a few percent at freezing, and something closer to 15 to 20 percent by minus 10 degrees Celsius, depending on the cell and how the BMS manages the pack. Charging below zero is blocked outright on most systems, which matters if your outages tend to happen during winter storms. A battery in an unheated garage behaves differently from one on an interior wall. Winter sun If you are counting on solar to recharge during a multi-day outage, check what the array produces in December rather than June. In mid-latitudes, winter yield can fall to a third of the summer figure. A two-day target sized on summer generation may turn out to be a one-day target in January, and the calculation should use the season when the risk actually occurs. The reserve you set Most systems hold a backup reserve that the daily cycle is not allowed to touch. Set it to 20 percent and you have given up a fifth of your capacity to insurance. That is often the right call, but it belongs in the sizing arithmetic rather than being discovered after installation when the battery refuses to discharge past a certain point. Leave room to grow Parallel packs share one bus; only the unit count changes between series. A modular battery lets you add capacity later, but only if the inverter and the communication bus support it. Confirm the expansion limit before buying, because not every wall-mounted battery can be extended, and mixing different generations is often restricted. GreenMore system Starting point Expansion Maximum Stacked battery, GM-ESS-B series 5.12 kWh Stack up to 4 modules 20.48 kWh Wall-mounted battery 5.12 kWh 1 to 8 units in parallel 40.96 kWh OEM battery system 10.24 kWh 1 to 10 units in parallel 102.4 kWh All-in-one system, GM-LEB6K 20.48 kWh Up to 32 units in parallel 655.4 kWh Start with enough storage for the essentials, add modules when an EV or a heat pump arrives, and keep the solar on the same system. The alternative, replacing the whole battery in three years because the first one could not be extended, is the expensive version of this decision. What to check before you buy Match the battery and the inverter. Their voltage windows, power rating and control protocol have to be compatible. A battery is only as useful as the inverter it pairs with, so confirm the combination works rather than buying the two separately on price. Check real certifications. Ask for the documents relevant to your market, such as CE and IEC for many regions, plus UN38.3 and MSDS for transport and handling. Safety testing to IEC 62619 is a good sign. Verify the certificate rather than relying on a logo on the datasheet. Compare usable capacity and warranty, not sticker size. Two batteries with the same nominal kWh can differ in usable energy, cycle life and warranty terms. Read the cycle definition and the warranty period together. GreenMore covers storage components for three years. Avoid undersizing on price. A battery that is regularly flattened or pushed past its limits will not reach its rated life. If the budget is tight, protect the essential loads and expand later rather than running a small unit at its limit every night. Match the configuration to the house: Home situation Typical usable capacity Configuration Apartment or small house, short outages 5 to 10 kWh Single wall-mounted battery, single phase Family home, one-night backup 10 to 20 kWh Wall or stacked system with hybrid inverter Large home or villa, three-phase loads 20 to 30 kWh Stacked modules with three-phase inverter Off-grid or two-day autonomy 30 kWh and up Multiple modules, often with a generator Where GreenMore fits GreenMore builds the battery and the inverter side of this calculation, from single wall-mounted packs to stacked systems and containerised storage. The residential range is on the home energy storage category page, and a worked system is on the 10 kWh home energy storage system page. If you send us your bill, appliance list, country and backup target, we can work through the sizing with you. Use the contact page or email export@gmsolarkit.com. Related reading: what an energy storage inverter actually does, how stackable batteries scale, and how to read a battery's kWh rating. PLPeter LuEnergy Storage Product Manager Frequently asked questions Is a 5 kWh battery enough for a house? For a small efficient home that only needs to keep lights, a refrigerator and internet running through a short outage, around 5 kWh of usable storage can be enough. It will not run heating, cooling or the whole home overnight, and it is tight where outages last more than a few hours. What is the most common home battery size? Most grid-connected family homes land between 10 and 20 kWh of usable capacity, which covers the essential loads through one night. The right point within that range depends on evening consumption, whether you heat with electricity, and how long local outages tend to last. Should I use nominal or usable capacity when sizing? Use usable capacity. Nominal capacity is the battery's full rating; usable capacity is what remains after the depth of discharge and efficiency limits. A 12 kWh nominal battery might deliver around 10 kWh to your appliances, so sizing from usable energy avoids coming up short. Does a bigger battery need a bigger inverter? Not automatically, but they should be sized independently. The battery sets how long you can run; the inverter sets how much you can run at once. Adding capacity without changing the inverter gives you longer runtime at the same power, which is often exactly what a one-night backup target needs. How much does cold weather reduce usable capacity? A few percent around freezing, and closer to 15 to 20 percent at minus 10 degrees Celsius, depending on the cell and the BMS strategy. Charging below zero is usually blocked, so a battery in an unheated space can supply power in a winter outage but cannot recharge until it warms up. Is it cheaper to add a battery or a generator for long outages? For frequent short outages and daily savings, a battery is clean, quiet and automatic. For rare multi-day events, a generator, or a hybrid system that uses the battery first and the generator for extended bad weather, usually costs less than buying enough storage for several days of autonomy. Updated on November 13, 2026

Subscribe To Our Newsletter

Stay up to date with GreenMore. We share new BIPV solar tile releases, product and certification updates, and field notes from our projects — no fluff, just the things that matter to installers, distributors, and system integrators. If there's something you'd like to see covered, drop us a line — we read every reply.

Copyright @ 2026 GreenMore All Rights Reserved. Network Supported

Sitemap / Blog / Xml / Privacy Policy

leave a message

leave a message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.
submit

Home

Products

WhatsApp

contact